JMobile Studio Softkey License
JMobile Studio Softkey License
OD2-P50W10I2 - 6036592
Mechanics/electronics
Supply voltage Vs DC 12 V ... 24 V
Power consumption ≤ 2.88 W 1)
Warm-up time ≤ 30 min
Housing material Plastic (PBT)
Window material Plastic (PMMA)
Connection type Cable, 2 m
Indication Distance bar graph, up to 8 status LEDs
Weight 70 g
Dimensions (W x H x D) 20.4 mm x 60 mm x 50 mm
Enclosure rating IP67
Protection class III
1) Without load, with current output.

Performance
Measuring range 40 mm ... 60 mm 1)
Target Natural objects
Repeatability 5 µm 2) 3) 4)
Linearity ± 20 µm 2) 3) 5)
Response time ≥ 1 ms
Measuring frequency ≤ 2 kHz 1)
Output time ≥ 0.5 ms
Light source Laser, red
visible red light
Laser class 2 (IEC 60825-1:2014, EN 60825-1:2014) 6)
Typ. light spot size (distance) 0.5 mm x 1 mm (50 mm)
Additional function Mean-value setting 1 … 64x, automatic sensitivity adjustment, Analog outputs can be taught in, Invertable analog output, Teach-in of digital output, Invertable switching output, multifunctional input: laser-off / external teach-in / trigger, switching mode: distance to object (DtO), switching mode: window (Wnd)
1) 6 % ... 90 % remission.
2) Measurement on 90 % remission (ceramic, white).
3) At averaging function medium.
4) Constant ambient conditions.
5) When calibrated in the application regularly.
6) Wavelength: 655 nm, max. output: 1 mW.

Interfaces
Digital output
Number 2 1)
Type PNP
Maximum output current IA ≤ 100 mA
Analog output
Number 1
Type Current output
Current 4 mA ... 20 mA, ≤ 300 Ω
Resolution 16 bit
Multifunctional input (MF) 1 x MF 2)
1) PNP: HIGH = VS - (< 2 V) / LOW = < 2 V; NPN: HIGH = < 2 V / LOW = VS.
2) MF can be used as laser-off, trigger, external teach-in, or deactivated; response time ≤ 3 ms.

Ambient data
Ambient temperature, operation –10 °C ... +40 °C
Ambient temperature, storage –20 °C ... +60 °C
Relative air humidity (non-condensing) 35 % ... 95 %
Temperature drift ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor)
Typ. Ambient light immunity

Artificial light: ≤ 3,000 lx

Sunlight: ≤ 10,000 lx
Vibration resistance 10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance 50 G (x, y, z axis 3 times each)
IN40-E0101K - 6027388
Features
Sensor principle Inductive
Number of safe outputs 2
Switching delay from state change Max. 50 ms 1)
Enable zone 10 mm ... 15 mm 2)
Safe switch off distance Sar 30 mm 2)
Actuation directions 5
Active sensor surfaces 1
Monitoring time minimum dwell time ≥ 0.2 s
1) During this time the output is switched off (Logical “0”), see response range.
2) Dependent on material. The indicated values refer to steel ST37.

Safety-related parameters
Safety integrity level SIL3 (IEC 61508)
Category Category 3 (EN ISO 13849)
Performance level PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 1.0 x 10-8
TM (mission time)

10 years (EN ISO 13849) 1)

20 years 2)
Type Type 3 (EN ISO 14119)
Actuator coding level Uncoded (EN ISO 14119)
Classification in compliance with IEC/EN 60947-5-3 PDF-M
1) At –25 °C ... +70 °C and 5 % ... 95 % relative air humidity.
2) At +10 °C ... +40 °C and 5 % ... 70 % relative air humidity.

Functions
Safe series connection With Flexi Loop (with diagnostics)

Interfaces
Connection type Plug connector, M12, 4-pin
Power indication ✔
Status display ✔

Electrical data
Protection class III (EN 50178)
Supply voltage Vs 24 V DC (19.2 V DC ... 30 V DC)
Power consumption 15 mA
Type of output Self-monitoring semiconductor outputs (OSSDs)

Mechanical data
Design Rectangular
Weight 0.22 kg
Material
Housing Zinc die cast (housing), PPE (cover)
Installation type Non-flush

Ambient data
Enclosure rating IP67 (IEC 60529)
Ambient operating temperature –25 °C ... +70 °C
Storage temperature –25 °C ... +70 °C
Vibration resistance 10 Hz ... 55 Hz, 1 mm (EN 60947-5-3)
Shock resistance 30 g, 11 ms (EN 60947-5-3)
IN40-E0109K - 6050281
Features
Sensor principle Inductive
Number of safe outputs 2
Switching delay from state change Max. 50 ms 1)
Enable zone 4 mm ... 20 mm 2)
Safe switch off distance Sar 45 mm 2)
Actuation directions 5
Active sensor surfaces 1
Monitoring time minimum dwell time ≥ 0.2 s
1) During this time the output is switched off (Logical “0”), see response range.
2) Dependent on material. The indicated values refer to steel ST37.

Safety-related parameters
Safety integrity level SIL3 (IEC 61508)
Category Category 3 (EN ISO 13849)
Performance level PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 1.0 x 10-8
TM (mission time)

10 years (EN ISO 13849) 1)

20 years 2)
Type Type 3 (EN ISO 14119)
Actuator coding level Uncoded (EN ISO 14119)
Classification in compliance with IEC/EN 60947-5-3 PDF-M
1) At –25 °C ... +70 °C and 5 % ... 95 % relative air humidity.
2) At +10 °C ... +40 °C and 5 % ... 70 % relative air humidity.

Functions
Safe series connection With Flexi Loop (with diagnostics)

Interfaces
Connection type Plug connector, M12, 4-pin
Power indication ✔
Status display ✔

Electrical data
Protection class III (EN 50178)
Supply voltage Vs 24 V DC (19.2 V DC ... 30 V DC)
Power consumption 30 mA
Type of output Self-monitoring semiconductor outputs (OSSDs)

Mechanical data
Design Rectangular
Weight 0.22 kg
Material
Housing Zinc die cast (housing), PPE (cover)
Installation type Non-flush

Ambient data
Enclosure rating IP67 (IEC 60529)
Ambient operating temperature –25 °C ... +60 °C
Storage temperature –25 °C ... +70 °C
Vibration resistance 10 Hz ... 55 Hz, 1 mm (EN 60947-5-3)
Shock resistance 30 g, 11 ms (EN 60947-5-3)
IMP12-1B5PSVC0B - 6050113
Features
Housing Cylindrical thread design
Thread size M12 x 1
Diameter Ø 12 mm
Pressure resistance ≤ 500 bar
Sensing range Sn 1.5 mm
Safe sensing range Sa 1.2 mm
Installation type Flush
Switching frequency 600 Hz
Connection type Male connector M12, 4-pin
Switching output PNP
Output function NO
Electrical wiring DC 3-wire
Enclosure rating IP68 1)
Special features High pressure resistant
Special applications Hydraulic application
1) Sensing face.

Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC
Ripple ≤ 20 % 1)
Voltage drop ≤ 2 V 2)
Time delay before availability ≤ 50 ms
Hysteresis 1 % ... 15 % 3)
Reproducibility ≤ 7 % 4) 5)
Temperature drift (of Sr) ≤ 15 %
EMC According to EN 60947-5-2
Continuous current Ia ≤ 200 mA
Vacuum resistance 10-8 Torr 6)
Large sealing ring 5.3 mm x 2.4 mm
Size support ring 10 mm x 5.9 mm x 1 mm
Short-circuit protection ✔
Reverse polarity protection ✔
Shock and vibration resistance 30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature –25 °C ... +80 °C
Housing material Stainless steel V2A, DIN 1.4305 / AISI 303
Sensing face material Ceramics, ZrO2
Sealing ring material FPM
Housing length 56 mm
Thread length 28 mm
Tightening torque, max. ≤ 40 Nm
1) Of VS.
2) With Ia = 200 mA.
3) Typ. 8%.
4) Ub = 20 ... 30 VDC.
5) Ta = 23 °C ± 5 °C.
6) Front.

Safety-related parameters
MTTFD 171 years
DCavg 0%
TM (mission time) 20 years

Reduction factors
Note The values are reference values which may vary
St37 steel (Fe) 1
Stainless steel (V2A, 304) Approx. 0.75
Aluminum (Al) Approx. 0.2
Copper (Cu) Approx. 0.12
Brass (Br) Approx. 0.34

Installation note
Remark Associated graphic see "Installation"
B 8 mm
C 12 mm
D 6 mm
F 12 mm
IM30-15NPS-ZC1 - 6020286
Features
Housing Cylindrical thread design
Housing Standard design
Thread size M30 x 1.5
Diameter Ø 30 mm
Sensing range Sn 15 mm
Installation type Non-flush
Switching frequency 200 Hz
Connection type Male connector M12, 4-pin
Switching output PNP
Output function NO
Electrical wiring DC 3-wire
Enclosure rating IP67 1)
1) According to EN 60529.

Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC
Ripple ≤ 10 % 1)
Voltage drop ≤ 1 V 2)
Time delay before availability ≤ 100 ms
Hysteresis 2 % ... 10 %
Reproducibility ≤ 2 % 3) 4)
Temperature drift (of Sr) ± 10 %
EMC According to EN 60947-5-2
Continuous current Ia ≤ 400 mA
Short-circuit protection ✔
Reverse polarity protection ✔
Power-up pulse protection ✔
Shock and vibration resistance 30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature –25 °C ... +70 °C
Housing material Brass, Nickel-plated brass
Sensing face material Plastic
Housing length 76 mm
Thread length 38 mm
Tightening torque, max. ≤ 60 Nm
OLM200-1002 - 1051658
Mechanics/electronics
Supply voltage Vs DC 18 V ... 30 V 1)
Ripple ≤ 5 Vpp 2)
Power consumption < 5.5 W
Initialization time 3 s
Enclosure rating IP65 (EN 60 529)
Protection class III
1) Limit values, reverse-polarity protected.
2) May not exceed or fall below Uv tolerances.

Performance
Measuring range 0 m ... 10,000 m 1)
Resolution 0.1 mm, 1 mm, 10 mm, 100 mm
Repeatability 0.15 mm 2)
Response time 10 ms 3)
Output time 2.5 ms
Light source LED, red
Accuracy of speed output ± 5 mm/s
Max. movement speed 7 m/s
Reading distance 100 mm, ± 20 mm
Barcode width 30 mm
1) Dependent on the set resolution and transfer protocol.
2) Statistical error 3 s, no warm-up time required.
3) Response time of digital output.

Interfaces
PROFIBUS DP ✔ , DPV0
Digital input Multifunctional input MF2
Digital output
Number 1 1)
Type PNP / NPN
Function Position, speed, control mark Q00 (off), Q01 (on), illumination on/off, service [failure (dirt/LED service life), no barcode tape, over/under temperature, out of measuring range 0 km > position > 10 km, internal error]
Maximum output current IA ≤ 100 mA 2)
1) Via multifunctional output MF1.
2) Outputs MF1 short-circuit protected.

Ambient data
Electromagnetic compatibility (EMC)

EN 61000-6-2

EN 61000-6-4
Ambient temperature, operation –30 °C ... +60 °C 1)
Ambient temperature, storage –40 °C ... +75 °C 2)
Typ. Ambient light immunity ≤ 5,000 lx 3)
Vibration resistance DIN/EN 60068-2-6, DIN/EN 60068-2-64
Shock resistance DIN/EN 60068-2-27
1) Temperatures < –20 °C with 5 min warm up time.
2) Max. 95 % humidity, non-condensing.
3) Typ. value at +25 °C ambient temperature.
WL4SLG-3P2232V - 1058258
Features
Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 15.3 mm x 55.4 mm x 22.2 mm
Housing design Washdown 1)
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max.

0 m ... 4.5 m 2)

3)

4)
Sensing range

0 m ... 2 m 2)

3)

4)
Type of light Visible red light
Light source Laser 5)
Light spot size (distance) Ø 1 mm (500 mm)
Wave length 650 nm
Laser class 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment Single teach-in button
Special applications Hygienic and washdown zones, Detecting transparent objects, Detecting small objects
1) Difference between standard/washdown and hygiene: The essential difference between a standard/washdown product and a hygiene product is that where the process and contact with the medium (activity in the vicinity of the food) are concerned, a hygiene product is designed in accordance with the latest standards and hygiene design guidelines, and materials are selected accordingly.
2) Reflective tape REF-AC1000.
3) To the object leading edge.
4) To ensure reliable operation, we recommend using REF-AC1000 reflective tape or reflective-tap reflectors such as P41F, PLV14-A, PLH25-M12, or PLH25-D12. Reflectors with large-scale triple structures must only be used if deemed suitable for the application.
5) Average service life: 50,000 h at TU = +25 °C.

Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA 3)
Switching output PNP 4)
Output function Complementary
Switching mode Light/dark switching 4)
Output current Imax. ≤ 100 mA
Response time ≤ 0.5 ms 5)
Switching frequency 1,000 Hz 6)
Connection type Male connector M8, 4-pin 7)
Circuit protection

A 8)

B 9)

C 10)
Protection class III
Weight 40 g
Polarisation filter ✔
Housing material Stainless steel, Stainless steel V4A (1.4404, 316L)
Optics material Plastic, PMMA
Enclosure rating

IP66

IP67

IP68

IP69K 11)
Special feature Detecting transparent objects
Ambient operating temperature –10 °C ... +50 °C
Ambient operating temperature extended –30 °C ... +55 °C 12) 13)
Ambient temperature, storage –30 °C ... +70 °C
1) Limit values when operated in short-circuit protected network: max. 8 A.
2) May not exceed or fall below Uv tolerances.
3) Without load.
4) Q = light switching.
5) Signal transit time with resistive load.
6) With light/dark ratio 1:1.
7) Max. tightening torque: 0.6 Nm.
8) A = VS connections reverse-polarity protected.
9) B = inputs and output reverse-polarity protected.
10) C = interference suppression.
11) Only in case of correctly mounted IP69K connecting cable.
12) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
13) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.

Safety-related parameters
MTTFD 655 years (EN ISO 13849-1) 1)
DCavg 0 %
1) Mode of calculation: Parts-Count-calculation.

Classifications
ECl@ss 5.0 27270902
ECl@ss 5.1.4 27270902
ECl@ss 6.0 27270902
ECl@ss 6.2 27270902
ECl@ss 7.0 27270902
ECl@ss 8.0 27270902
ECl@ss 8.1 27270902
ECl@ss 9.0 27270902
ECl@ss 10.0 27270902
ECl@ss 11.0 27270902
ETIM 5.0 EC002717
ETIM 6.0 EC002717
ETIM 7.0 EC002717
ETIM 8.0 EC002717
UNSPSC 16.0901 39121528
WL4SLG-3K2432VS01 - 1065697
Features
Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 15.3 mm x 55.4 mm x 22.2 mm
Housing design Washdown 1)
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max.

0 m ... 4.5 m 2)

3)
Sensing range

0 m ... 2 m 2)

3)
Type of light Visible red light
Light source Laser 4)
Light spot size (distance) Ø 1 mm (500 mm)
Wave length 650 nm
Laser class 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment Single teach-in button
Off delay 16 ms
Special applications Hygienic and washdown zones, Detecting transparent objects, Detecting small objects
Special features Deactivation delay, 15 ms (± 5 %)
1) Difference between standard/washdown and hygiene: The essential difference between a standard/washdown product and a hygiene product is that where the process and contact with the medium (activity in the vicinity of the food) are concerned, a hygiene product is designed in accordance with the latest standards and hygiene design guidelines, and materials are selected accordingly.
2) Reflective tape REF-AC1000.
3) To ensure reliable operation, we recommend using REF-AC1000 reflective tape or reflective-tap reflectors such as P41F, PLV14-A, PLH25-M12, or PLH25-D12. Reflectors with large-scale triple structures must only be used if deemed suitable for the application.
4) Average service life: 50,000 h at TU = +25 °C.

Mechanics/electronics
Supply voltage 10 V DC ... 24 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA 3)
Switching output PNP 4)
Output function Complementary
Switching mode Light/dark switching 4)
Output current Imax. ≤ 50 mA
Response time ≤ 0.33 ms 5)
Switching frequency 1,500 Hz 6)
Connection type Male connector M12, 4-pin 7)
Circuit protection

A 8)

B 9)

C 10)
Protection class III
Weight 100 g
Polarisation filter ✔
Special device ✔
Housing material Stainless steel, Stainless steel V4A (1.4404, 316L)
Optics material Plastic, PMMA
Enclosure rating

IP66

IP67

IP68

IP69K 11)
Special feature Detecting transparent objects
Ambient operating temperature –10 °C ... +50 °C
Ambient operating temperature extended –30 °C ... +55 °C 12) 13)
Ambient temperature, storage –30 °C ... +70 °C
1) Limit values when operated in short-circuit protected network: max. 8 A.
2) May not exceed or fall below Uv tolerances.
3) Without load.
4) Q = light switching.
5) Signal transit time with resistive load.
6) With light/dark ratio 1:1.
7) Max. tightening torque: 0.7 Nm.
8) A = VS connections reverse-polarity protected.
9) B = inputs and output reverse-polarity protected.
10) C = interference suppression.
11) Only in case of correctly mounted IP69K connecting cable.
12) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
13) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.

Safety-related parameters
MTTFD 655 years (EN ISO 13849-1) 1)
1) Mode of calculation: Parts-Count-calculation.

Classifications
ECl@ss 5.0 27270902
ECl@ss 5.1.4 27270902
ECl@ss 6.0 27270902
ECl@ss 6.2 27270902
ECl@ss 7.0 27270902
ECl@ss 8.0 27270902
ECl@ss 8.1 27270902
ECl@ss 9.0 27270902
ECl@ss 10.0 27270902
ECl@ss 11.0 27270902
ETIM 5.0 EC002717
ETIM 6.0 EC002717
ETIM 7.0 EC002717
ETIM 8.0 EC002717
UNSPSC 16.0901 39121528
DOL-0804-G05MNI - 6059194
echnical specifications
Accessory group Plug connectors and cables
Accessory family Connecting cables
Connection type head A Female connector, M8, 4-pin, straight
Connection type head B Flying leads
Connection type Flying leads
Connector material PUR
Connector color Blue
Locking nut material Stainless steel (V4A/1.4404)
Tightening torque 0.4 Nm
Width across flats 10
Cable 5 m, 4-wire, PVC
Jacket material PVC
Jacket color Gray
Cable diameter 4.8 mm
Conductor cross-section 0.25 mm²
Shielding Unshielded
Bending radius
Flexible use > 10 x cable diameter
Stationary position > 5 x cable diameter
Reference voltage
≤ 30 V
Rated impulse voltage 0.8 kV
Current loading 4 A
Signal type Sensor/actuator cable
Application Hygienic and washdown zones
Note

This product is generally resistant to chemical cleaning agents (see ECOLAB). Please do not use cleaning agents of any other Kind. 1)

Not resistant against lactic acid & hydrogen peroxide (H2O2) 2)
Authorizations

Ecolab

UL
UL File No. CYJV.E335179
Enclosure rating IP65/ IP67/ IP69K
Ambient operating temperature
Flexible use –5 °C ... +80 °C
Stationary position –30 °C ... +80 °C
Head –25 °C ... +85 °C

1) Tested detergent: 3% P3 – topax 990, 5% P3 – topoactive 200, 5% P3 – topax 52, 3% P3 – topax 66, 3% P3 – topactive OKTO; Insulating material group: Cat I.
2) Insulating material group: Cat I.
SACC-M 8MS-3CON-M-SW - 1501252
Connector, Universal, 3-position, Plug straight M8, A, Screw connection, knurl material: Nickel-plated brass, external cable diameter 3.5 mm ... 5 mm
SACC-M 8FS-3CON-M-SW - 1506888
Connector, Universal, 3-position, Socket straight M8, A, Screw connection, knurl material: Nickel-plated brass, external cable diameter 3.5 mm ... 5 mm
XPPC 10-200-i3 (IPC)
Exor Make IPC with following specifications:

• Dimension 382.2(W)x251.4(H)x51.7(D)mm
• Cut Out Size (W x H) 370.5x240.mm
• Panel size/resolution 15.6" 16:9 1920x1080
• Luminance 450 cd/m² LED
• Touch screen 10 Point Capacitive
• CPU: On board 11th Gen, Intel core i3-1115G4E processor, dual core 2.2 GHz base frequency, 6M Cache
• Memory 8 GB DDR3L
• CFast socket One External CFast socket
• HDD Drive Bay 256 GB SSD
• I/O port: Isolation 2x RS232/422/485 by BIOS setting, 2xGbE, 1xVGA, 1xLine-out, 2xUSB 2.0, 1xUSB 3.0, PS2 KB/MS
• Extension 2xmini-PCIe
• Mounting Panel/Wall/Stand/VESA 100x100mm
• Embedded Image (QVL,
• Optional) Windows 10 64 bit
• Operating Temp. 0°C to 50°C
• Vibration 1Grms with HDD by IEC68 2-
• 64@SINE
• Shock 20G with HDD by IEC68 2-27@wall
• mount, half sine
• Weight 4.3Kgs
• Mounting Bracket for XPPC10-200
• 19VDC Power adapter
FLT-SEC-P-T1-1C-440/35-FM - 2905987
Plug-in lightning current arrester for higher nominal voltages, according to Type 1/Class I, for 1-phase power supply networks in TN and IT versions (L1, PE).
KTX-WP9114224IZZZZ - 1078087
Features
Special applications Standard
Device type Standard
Dimensions (W x H x D) 30 mm x 53 mm x 78.5 mm
Sensing distance ≤ 13 mm
Sensing distance tolerance ± 5 mm
Housing design Large
Light source LED, RGB 1)
Wave length 470 nm, 525 nm, 625 nm
Light emission Short device side
Light spot size 0.9 mm x 3.8 mm
Light spot direction Vertical 2)
Receiving filters None
Teach-in mode 1-point teach-in, 2-point teach-in, teach-in dynamic, auto mode
Output function Light/dark switching
Delay time Adjustable
Special features -
Delivery status 2-point teach-in
Parameter presettings None
1) Average service life: 100,000 h at TU = +25 °C.
2) In relation to long side of housing.

Mechanics/electronics
Supply voltage 10.8 V DC ... 28.8 V DC 1)
Ripple ≤ 5 Vpp 2)
Current consumption < 100 mA 3)
Switching frequency 50 kHz 4) 5)
Response time 10 µs 6) 7)
Jitter 5 µs 8)
Switching output PNP
Switching output (voltage) PNP: HIGH = VS - 3 V / LOW = 0 V
Output current Imax. 100 mA 9)
Input, teach-in (ET) Teach: U = 10 V ... < VS
Input, blanking input (AT) Blanked: U = 10 V ... < Uv
Input, fine/coarse (F/C) Coarse: U = 10 V ... < Uv
Input, light/dark (L/D) Light: U = 10 V ... < Uv
Retention time (ET) 25 ms, non-volatile memory
Connection type Male connector M12, 4-pin
Protection class III
Circuit protection

UV connections, reverse polarity protected

Output Q short-circuit protected

Interference pulse suppression
Enclosure rating IP67
Weight 94 g
Housing material Plastic, VISTAL®
Optics material Plastic, COP
GRSE18S-P1142 - 1069629
Features
Sensor/ detection principle Through-beam photoelectric sensor
Dimensions (W x H x D) 18 mm x 18 mm x 38.1 mm
Housing design (light emission) Cylindrical
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 0 m ... 15 m
Sensing range 0 m ... 10 m
Type of light Visible red light
Light source PinPoint LED 1)
Light spot size (distance) Ø 250 mm (10 m)
Wave length 650 nm
Adjustment Potentiometer, 270°
Potentiometer
Indication
LED indicator green Operating indicator
Static: power on
LED indicator yellow Status of received light beam
Static: object not present
Static off: object present
1) Average service life: 100,000 h at TU = +25 °C.

Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA
Switching output PNP
Output function Complementary
Switching mode Light/dark switching
Output current Imax. ≤ 100 mA 3)
Response time < 500 µs 4)
Switching frequency 1,000 Hz 5)
Connection type Cable, 4-wire, 2 m 6)
Cable material PVC
Circuit protection

A 7)

B 8)

D 9)
Protection class III
Housing material Metal, Nickel-plated brass and ABS
Optics material Plastic, PMMA
Enclosure rating IP67
Items supplied Fastening nuts (4 x)
Electromagnetic compatibility (EMC) EN 60947-5-2
Test input Sender OFF at "Test" 0 V
Ambient operating temperature –25 °C ... +55 °C 10)
Ambient temperature, storage –40 °C ... +70 °C
UL File No. NRKH.E348498 & NRKH7.E348498
Part number of individual components 2075623 GRS18S-D1341 2075658 GRE18S-P1132
1) Limit values. Operated in short-circuit protected network: max. 8 A.
2) May not exceed or fall below Uv tolerances.
3) At Uv > 24 V or ambient temperature > 49 °C, IA max. = 50 mA.
4) Signal transit time with resistive load.
5) With light/dark ratio 1:1.
6) Do not bend below 0 °C.
7) A = VS connections reverse-polarity protected.
8) B = inputs and output reverse-polarity protected.
9) D = outputs overcurrent and short-circuit protected.
10) At Uv <=24V and IA<50mA.
IQE17-05NPSKW2S - 1069411
Housing Rectangular
Housing Rectangular
Dimensions (W x H x D) 17 mm x 17 mm x 29.5 mm
Sensing range Sn 5 mm
Safe sensing range Sa 4.05 mm
Installation type Non-flush
Switching frequency 1,000 Hz
Connection type Cable, 3-wire, 2 m
Switching output PNP
Output function NO
Electrical wiring DC 3-wire
Enclosure rating IP67 1)
1)
According to EN 60529.
Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC
Ripple ≤ 10 %
Voltage drop ≤ 2 V
Time delay before availability ≤ 100 ms
Hysteresis 5 % ... 15 %
Reproducibility ≤ 2 %
Temperature drift (of Sr) ± 10 %
EMC According to EN 60947-5-2
Continuous current Ia ≤ 200 mA
Cable material PVC
Short-circuit protection ✔
Reverse polarity protection ✔
Power-up pulse protection ✔
Ambient operating temperature –25 °C ... +75 °C
UM30-213113 - 6036918
Mechanics/electronics
Supply voltage Vs DC 9 V ... 30 V 1) 2)
Power consumption ≤ 2.4 W 3)
Initialization time < 300 ms
Design Cylindrical
Housing material

Metal (nickel-plated brass, PBT)

Ultrasonic transducer: polyurethane foam, glass epoxy resin
Thread size M30 x 1.5
Connection type Male connector, M12, 5-pin
Indication LED display, 2 x LED
Weight 150 g
Sending axis Straight
Dimensions (W x H x D) 30 mm x 30 mm x 84 mm
Enclosure rating IP65 / IP67
Protection class III
1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
2) 15 V ... 30 V when using the analog voltage output.
3) Without load.

Performance
Operating range, limiting range 200 mm ... 1,300 mm, 2,000 mm
Target Natural objects
Resolution ≥ 0.18 mm
Repeatability ± 0.15 % 1)
Accuracy ± 1 % 2) 3)
Temperature compensation ✔
Response time 92 ms 4)
Output time 23 ms
Ultrasonic frequency (typical) 200 kHz
Detection area (typical) See diagrams
Additional function Teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), reset to factory default
1) In relation to the current measured value, minimum value ≥ resolution.
2) Referring to current measurement value.
3) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.
4) Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.
SUBCON-PLUS-PROFIB/PG/SC2 - 2708245
D-SUB connector, 9-pos., male connector, 35° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks
VAL-MS 320/3+1 - 2859178
Surge protective device, 4-channel (in 3+1 circuit), for installation on NS 35/7,5 voltage: 230 V AC