Home
Product
Hardware
Controllers
Remote IOs
HMI & IPS
Software
SCADA Software
Programming Software
HMI Softwares
Cloud Solutions
Cloud database
Remote Monitoring
IOT Dashboards
Sensors
Proximity Sensors
1/2/3/4D Sensors
Saftey Sensors
Blog
Courses
Contact us
Jobs
Forum
Events
Shop
0
0
Sign in
Contact Us
Public Price
Public Price
Prev
177
178
179
180
181
182
183
Next
Sort by
Catalog price: High to Low
Catalog price: Low to High
Name: A to Z
Name: Z to A
Show categories
All Products
Plug connectors and cables
Phoenix Contact
PLC/ IO Modules
Power Supplies
Redundancy module
Memory
Program / configuration memory
Safety controller
Antenna cable
Connecting cable
Fan
Multiplexer
Controller
Bus connector
Extension module
Box PC
I/O module
Communication module
Special function module
Safety module
Power module
Starter kit
Module carrier
Cover
Bus coupler
Inline function terminal
Inline terminal
Inline ME terminal
Branch terminal
Potential distributors
Field multiplexer
Distributed I/O device
Feed-through terminal block
End cover
Screw bridge
Insertion bridge
Separating plate
Partition plate
Female test connector
Test plugs
Insulating sleeve
Fixed bridge
Fuse modular terminal block
Fuse terminal block
Lever-type disconnect terminal block
Double-level terminal block
Spacer plate
Knife disconnect terminal block
Disconnect terminal block
Switching jumper
Bolt connection terminal block
Cover profile
Test disconnect terminal block
High Current Connectors
Type 1+2 combined lightning current and surge arrester
Lightning/surge arrester type 1/2
Type 1/2 surge protection plug
Type 2 surge arrester
Type 2 surge protection base element
Power supply unit
Relay base
Relay retaining bracket
Single relay
Plug-in module
Timer relay
Signal conditioner
Repeater power supply
Temperature measuring transducer
Signal duplicator
Marker for terminal blocks
Label
Thermal transfer printer
Magazine
Ink ribbon
Ferrule
Stripping tool
Crimping pliers
End clamp
Industrial Ethernet Switch
Multi-level terminal block
Relay Module
Remote bus cable
Surge protection device
Screwdriver
Antenna
Base unit
Cable
Component terminal block
RJ45 connector
Distribution block
Double-level spring-cage terminal block
Printed-circuit board connector
Interface converters
FO converters
Frequency transducer
Frequency converter
Fuse
Hybrid motor starter
I/O extension module
System package
Miniature solid-state relay
nanoLC module
Operator terminal
Plug-in bridge
Potential collective terminal
Router
Sensor/actuator cable
Connector
Safety relays
Software
Surge protection base-element
Signaling system
Touch panel
Uninterruptible power supply
Type 2 surge protection plug
Wireless module
Cable tie
Zack marker strip
Fork-type cable lug
Continuous plug-in bridge
FO patch cable
DIN rail bus connectors
License
Type 3 surge protection device
Sensor/actuator box
Sensor/actuator terminal block
D-SUB bus connector
Passive module
Ground modular terminal block
Sensor/actuator box header
EXOR
EXOR International
Ex700 Series
Jsmart 700 Series
Esmart Series
HMI Add-Ons Plugins
Mounting brackets and plates
Type 3 surge protection device
SICK Sensors
Encoders
Incremental encoders
Absolute encoders
Proximity sensors
Capacitive proximity sensors
Inductive Proximity Sensors
Contrast Sensors
Fiber-optic Sensors and fibers
Fork sensors
Magnetic Cylinder Sensors
Photoelectric sensors
Distance Sensors
Detection and Ranging Solutions
Displacement measurement sensors OD Mini / OD Mini Prime
Safety Light Curtains
Accessories
level sensors
Fluid sensors
Safety laser scanners
GL6-P3211 - 1068921
Features
Functional principle Photoelectric retro-reflective sensor
Functional principle detail Dual lens
Sensing range max. ≤ 6 m 1)
Sensing range ≤ 5 m 1)
Polarisation filters Yes
Emitted beam
Light source PinPoint LED 2)
Type of light Visible red light
Light spot size (distance) Ø 8 mm (350 mm)
Key LED figures
Wave length 650 nm
Adjustment Potentiometer, 270°
1) Reflector PL80A.
2) Average service life: 100,000 h at TU = +25 °C.
Safety-related parameters
MTTFD 1,705 years
DCavg 0 %
Electrical data
Supply voltage UB 10 V DC ... 30 V DC 1)
Ripple ± 10 % 2)
Current consumption 30 mA 3)
Protection class III
Digital output
Type PNP
Signal voltage PNP HIGH/LOW VS - (≤ 3 V) / approx. 0 V
Output current Imax. ≤ 100 mA 4)
Response time < 625 µs 5)
Switching frequency 1,000 Hz 6)
Switching mode Light/dark switching
Switching mode selector Selectable via light/dark selector
Circuit protection
A 7)
B 8)
D 9)
1) Limit values when operated in short-circuit protected network: max. 8 A.
2) May not exceed or fall below Uv tolerances.
3) Without load.
4) At Uv > 24 V, IA max. = 50 mA.
5) Signal transit time with resistive load.
6) With light/dark ratio 1:1.
7) A = VS connections reverse-polarity protected.
8) B = inputs and output reverse-polarity protected.
9) D = outputs overcurrent and short-circuit protected.
Mechanical data
Housing Rectangular
Dimensions (W x H x D) 12 mm x 31.5 mm x 21 mm
Connection Connector M8, 3-pin
Material
Housing Plastic, ABS/PC
Front screen Plastic, PMMA
Weight 20 g
Ambient data
Enclosure rating IP67
Ambient operating temperature –25 °C ... +55 °C 1)
Ambient temperature, storage –40 °C ... +70 °C
UL File No. NRKH.E348498 & NRKH7.E348498
1) Temperature stability following adjustment +/-10 °C.
WLL180T-L632 - 6050762
Features
Device type Fiber-optic sensors
Device type detail Base unit 1)
Dimensions (W x H x D) 10.5 mm x 34.6 mm x 71.9 mm
Housing design (light emission) Rectangular
Sensing range max. 0 m ... 20 m (Through-beam system) 2) 3)
Sensing range
0 mm ... 1,400 mm, Proximity system 4) 5)
0 m ... 18 m, Through-beam system 2) 3)
Focus Approx. 65° 6)
Type of light Visible red light
Light source LED 7)
Angle of dispersion Approx. 65° 6)
Wave length 650 nm
Adjustment
Menu-controlled
Single teach-in button
Cable
Indication Display
Display LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters
1) Up to 15 expansion units can be connected.
2) Sensing range with 8 ms response time. Reduction with shorter response time (see tables LL3/WLL180T).
3) LL3-TX01.
4) Object with 90% remission (based on standard white DIN 5033). Sensing range at 8 ms response time. Reduced at shorter response times (see LL3 / WLL180T tables).
5) LL3-DK06.
6) See LL3 fiber-optic data.
7) Average service life: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage 12 V DC ... 24 V DC 1)
Ripple ≤ 10 % 2)
Current consumption 50 mA 3)
Switching output NPN
Number of switching outputs 2
Switching mode Light/dark switching
Switching mode selector Manually selectable
Response time
≤ 16 µs 4)
≤ 70 µs
≤ 250 µs
≤ 2,000 µs
≤ 8,000 µs
Switching frequency
31.2 kHz
7.1 kHz
2 kHz
250 Hz
62.5 Hz
Time functions
Without time delay
Off delay
On delay
ON and OFF delay
One shot
Delay time Programmable, 0 ms ... 9,999 ms
Input Multifunctional input MF
Connection type Cable, 5-wire, 2 m 5)
Cable material PVC
Conductor cross section 0.2 mm²
Circuit protection
A 6)
B 7)
C 8)
D 9)
Protection class III
Weight 25 g
Housing material Plastic, ABS/PC
Enclosure rating IP50 10)
Items supplied BEF-WLL180 mounting bracket
Ambient operating temperature –25 °C ... +55 °C
Ambient temperature, storage –40 °C ... +70 °C
UL File No. NRKH2.E300503 & NRKH8.E300503
1) +- 10%.
2) May not exceed or fall below Uv tolerances.
3) Without load.
4) Selectable.
5) Do not bend below 0 °C.
6) A = VS connections reverse-polarity protected.
7) B = inputs and output reverse-polarity protected.
8) C = interference suppression.
9) D = outputs overcurrent and short-circuit protected.
10) With correctly attached fibre-optic cable LL3 and closed protection hood.
FL MC 1000 SC - 2891320
FO converter with SC duplex fiber optic connection (1300 nm), for converting 100Base-TX to multi-mode fiberglass. Auto MDI(X) function and comprehensive link diagnostics. DIN rail mountable.
TMM55E-PMH060 - 1073782
Performance
Number of axis 2
Measuring range ± 60°
Resolution 0.06°
Accuracy ± 0.5°
Compensated cross-sensitivity (2-dimensional) Typ. ± 1.2°, max. ± 2.4°
Temperature coefficient (zero point) Max. ± 0.009°/K
Limit frequency 18 Hz
Sampling rate 1.95 kHz
Interfaces
Communication interface Analog / Current
Current output 4 mA ... 20 mA
Load resistance ≤ 930 Ω
Initialization time 75 ms
Electrical data
Connection type Cable, 5-wire, with male connector, M12, 5-pin, 0.2 m
Supply voltage 11 V DC ... 30 V DC
Current consumption 15 … 45 mA
Reverse polarity protection ✔
Short-circuit protection of the outputs ✔
MTTFd: mean time to dangerous failure 378 years (EN ISO 13849-1) 1)
1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Mechanical data
Dimensions 65 mm x 35 mm x 20 mm
Weight 55 g (with cable)
Housing material Plastic (ABS)
Material, cable PUR
Ambient data
EMC EN 61326-1, EN ISO 14982, EN ISO 13309
Enclosure rating IP65, IP67
Operating temperature range –40 °C ... +80 °C
Storage temperature range –40 °C ... +85 °C
Resistance to shocks 100 g, 6 ms (according to EN 60068-2-27)
Resistance to vibration 10 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
SAC-4P-2,0-E20/M12FS - 1410889
Sensor/actuator cable, 4-position, free cable end, on Socket straight M12, coding: A, cable length: 2 m
SAC-5P-2,0-E20/M12FS - 1410911
Sensor/actuator cable, 5-position, free cable end, on Socket straight M12, coding: A, cable length: 2 m
SAC-5P- 5,0-PVC/M12FS - 1453889
Sensor/actuator cable, 5-position, PVC, black RAL 9005, free cable end, on Socket straight M12, coding: A, cable length: 5 m
TRIO-PS/1AC/24DC/10 - 2866323
Primary-switched TRIO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/10 A
MZC1-2V2PS-KU0 - 1059738
Features
Cylinder type C-slot
Cylinder types with adapter
SMC rail CDQ2
SMC rail ECDQ2
Round body cylinder
Profile cylinders and tie-rod cylinders
Housing length 23.7 mm
Switching output PNP
Switching frequency 1,000 Hz
Output function NO
Electrical wiring DC 3-wire
Enclosure rating IP68, IP69K 1) 2)
1) According to EN 60529 (IP 67 / IP 68).
2) According to DIN 40050 (IP 69K).
Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC
Power consumption 8 mA, without load
Voltage drop ≤ 2.5 V
Continuous current Ia ≤ 100 mA
Protection class III
Response sensitivity, typ. 2.2 mT
Overrun distance, typ. 4 mm
Hysteresis, typ. ≤ 0.8 mT
Reproducibility ≤ 0.1 mT 1)
Reverse polarity protection Yes
Short-circuit protection Yes
Power-up pulse protection Yes
Ambient operating temperature –30 °C ... +80 °C
Shock and vibration resistance 30 g, 11 ms / 10 ... 55 Hz, 1 mm
EMC According to EN 60947-5-2
Connection type Cable, 3-wire, 2 m
Connection type Detail
Conductor cross section 0.09 mm²
Cable diameter Ø 2.2 mm
Bending radius With fixed installation > 2 x cable diameter
For flexible use > 5 x cable diameter
Cable outlet Axial
Material
Housing Plastic
Cable PUR
UL File No. NRKH.E181493 & NRKH7.E181493
1) Ub and Ta constant.
Safety-related parameters
MTTFD 2,461 years
DCavg 0 %
TM (mission time) 20 years
RZT7-03ZRS-KW0 - 1070852
Features
Cylinder type T-slot
Cylinder types with adapter
Profile cylinder
Tie rod cylinder
Round body cylinder
Dovetail groove cylinder
SMC rail CDQ2
SMC rail ECDQ2
Housing length 29.5 mm
Switching output Reed
Switching frequency 400 Hz
Output function NO
Electrical wiring AC/DC 3-wire
Enclosure rating
IP65 1)
IP67
1) According to EN 60529.
Mechanics/electronics
Supply voltage 5 V AC/DC ... 30 V AC/DC
Voltage drop ≤ 0.1 V 1)
Continuous current Ia
≤ 500 mA 2)
≤ 300 mA 3)
Switching capacity ≤ 6 W
Protection class III
Response sensitivity, typ. 3 mT
Overrun distance, typ. 10 mm
Reproducibility ≤ 0.1 mT 4)
Reverse polarity protection Yes
Status indicator LED Yes
Ambient operating temperature –30 °C ... +70 °C
Shock and vibration resistance 30 g, 11 ms / 10 ... 55 Hz, 1 mm
EMC According to EN 60947-5-2
Connection type Cable, 3-wire, 2 m
Connection type Detail
Conductor cross section 0.12 mm²
Cable diameter Ø 2.9 mm
Bending radius With fixed installation > 10 x cable diameter
For flexible use > 15 x cable diameter
Cable outlet Axial
Material
Housing Plastic
Cable PVC
UL File No. NRKH.E181493 & NRKH7.E181493
1) For cable length up to 0.3 m.
2) DC.
3) AC.
4) Ub and Ta constant.
Safety-related parameters
MTTFD 41,230 years
DCavg 0 %
TM (mission time) 20 years
B10d 10,000,000 Switching cycles 1)
1) Only for devices containing electro-mechanical components. In this case, the MTTFD value of the entire device must be calculated from the given B10D value, the number of switching cycles and the given MTTFD value.
PBS2-RB010SG1SSDNMA0Z - 6073951
Features
Medium Liquid, gaseous
Pressure type Gauge pressure
Pressure unit bar
Measuring range
0 bar ... 10 bar
0 psi ... 145 psi
Process temperature –20 °C ... +85 °C
Maximum ohmic load RA
4 mA ... 20 mA (RA ≤ 0.5 kOhm)
0 V ... 10 V, 3-wire (RA > 10 kOhm)
Zero point adjustment Max. + 3 % of span
Output signal IO-Link/PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
Rotatable housing
Display against housing with electrical connection: 330 °
Housing against process connection: 320 °
Display
14-Segment LED, red, 4-digit, character height 9 mm, can be rotated electronically by 180°
Update: 1,000, 500, 200, 100 ms (adjustable)
Mechanics/electronics
Process connection G ¼ A according to DIN 3852-E
Wetted parts
Pressure connection: stainless steel 316L
Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH)
Internal transmission fluid Silicone oil (only with pressure ranges < 0 bar ... 10 bar and ≤ 0 bar abs ... 25 bar abs)
Pressure port 3.5 mm, Standard
Housing material Lower body: stainless steel 304, Plastic head: PC + ABS, Buttons: TPE-E, Display window: PC
Connection type Round connector M12 x 1, 4-pin, IP67
Supply voltage 15 V DC ... 35 V DC
Power consumption
45 mA (for configurations without analog output signal)
70 mA (for configurations with analog output signal)
Total current consumption Max. 600 mA (including switching current)
Electrical safety
Protection class: III
Overvoltage protection: 40 V DC
Short-circuit protection: QA, Q1, Q2 towards M
Reverse polarity protection: L+ to M
Isolation voltage 500 V DC
CE-conformity EMC Directive: 2014/30 / EU (EN 61326-1:2013; EN 61326-2-3:2013), Pressure equipment directive: 2014/68 / EU, Hazardous materials (RoHS): 2011/65 / EU (EN 50581:2012)
Weight sensor Approx. 220 g
Seal NBR seal installed, FPM/FKM seal included
Enclosure rating IP67 / IP67
Protection class III ✔
MTTF 104 years
Performance
Non-linearity ≤ ± 0.25 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
Accuracy ≤ ± 0.5 % of the span
Setting accuracy of switching outputs ≤ ± 0.5 % of span
Response time ≤ 5 ms
Long-term drift/one-year stability
≤ ± 0.1 % of the span according to IEC 61298-2
≤ 0.2 % of the span According to IEC 61298-2 for measuring range ≤ 0.6 bar or flush-mounted membrane (0 psi ... 10 psi)
Temperature coefficient in rated temperature range Average TC of the zero point: ≤± 0.16% of the span / 10 K, Average TC of the span ≤± 0.16% of the span / 10 K
Rated temperature range 0 °C ... +80 °C
Service life Minimum 100 Mio. load cycles
Ambient data
Ambient temperature –20 °C ... +80 °C
Storage temperature –20 °C ... +70 °C
Relative humidity ≤ 75 %
Shock load 50 g, 6 ms according to IEC 60068-2-27 (mechanical shock)
Vibration load 20 g, 10 Hz ... 2,000 Hz (IEC 60068-2-6, at resonance)
FTMG-ISD25AXX - 1100213
Features
Measurement principle Calorimetric (flow, temperature), piezoresistive (pressure)
Medium Compressed air (air quality ISO 8573-1:2010 [3:4:4]), helium, argon, nitrogen, carbon dioxide
Measured values Mass, Mass flow rate, volume, Volumetric flow rate, Power, Flow velocity, pressure, temperature
Nominal width measuring tube DN 25
Measuring range
Standard 14.7 l/min ... 2,945.2 l/min 1)
0.5 m/s ... 100 m/s 1)
Enhanced 2,945.2 l/min ... 4,417.9 l/min 1)
100 m/s ... 150 m/s 1)
Process temperature –20 °C ... +60 °C
Process pressure 0 bar ... 16 bar
Communication interface IO-Link, IO-Link V1.1
Temperature measurement ✔
Pressure measurement ✔
Indication ✔
128 x 128 pixels, adjustable rotary OLED display (90° steps) and 4 pushbuttons
1) Reference conditions according to DIN 1343 (atmospheric pressure 1,013 mbar, compressed air temperature 0 °C).
Performance
Measurement accuracy
Standard ± 3 % of the measured value + 0.3% of the measuring range limit value (extended measuring range) 1)
Enhanced ± 8 % of the measured value + 1% of the measuring range limit value (extended measuring range)
Repeatability ± 1.5 % From measured value 1)
Response time < 0.3 s
Temperature measurement
Measurement accuracy (temperature) ± 2 °C 2)
Repeatability (temperature) ± 0.5 °C 2)
Pressure measurement
Measurement accuracy (pressure) ± 1.5 % of measuring range end value 3)
Non-linearity (pressure) ± 0.5 % from measuring range 3)
Repeatability (pressure) ± 0.2 % from measuring range 3)
1) Reference conditions during measurement: media conditions: air according to ISO 8573-1:2010 [3:4:4] or better; static pressure = 7 ± 0.2 bar (abs.); medium temperature 22 ± 3 °C; straight inlet zone > 250xDN; average filter can be parameterized by customer: 10 seconds / ambient conditions: ambient temperature 15 °C ... 25 °C; ambient pressure: 1013 mbar / measured value via digital interface.
2) When flow rate ≥ 10% of the measuring range limit value (standard measuring range).
3) Evaluation according to DIN EN 61298-2 best fit straight line.
Electronics
Supply voltage 17 V DC ... 30 V DC 1)
Power consumption < 4.5 W at 24 V DC without output load
Initialization time ≤ 10 s
Protection class III
Connection type M12 x 1 round connector, 5-pin, A-coded
Output signal 1x analog output 4 mA ... 20 mA + 1x digital/analog output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable), frequency pulse output + 1x digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud)
Output load 4 mA ... 20 mA, max. 500 ohm
Lower signal level 3.5 mA ... 3.8 mA
Upper signal level 20.5 mA ... 21.5 mA
Inaccuracy
QA Pin2: < 0.5% full-range (20 mA)
Q2 Pin5: < 0.5% full-range (20 mA)
Digital output ≤ 100 mA
Signal voltage HIGH > Uv - 2 V
Signal voltage LOW ≤ 2 V
Inductive load ≤ 1 H
Capacitive load ≤ 100 nF (2.5 nF, IO-Link mode)
MTTF > 100 years
1) All connections are reverse polarity and overload protected. Q1 and Q2 are short-circuit protected. Use an energy-limited circuit for the voltage supply as per UL61010-1 3. Outp.
Mechanics
Process connection G 1 (according to DIN ISO 228-1)
Wetted parts Probe: stainless steel 1.4305, PA6; seal: FKM (Viton®); measurement channel: aluminum
Housing material PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301
Enclosure rating IP65/IP67 (according to IEC 60529) 1)
Weight Approx. 685 g
1) Not UL-tested.
Ambient data
Ambient operating temperature –20 °C ... +60 °C 1)
Ambient temperature, storage –40 °C ... +85 °C
1) According to the UL approval: degree of contamination 3 (UL61010-1: 2012-05); air humidity: 80% at temperatures up to 31 °C; installation altitude: max. 3,000 m above sea level.
FLT-SEC-H-T1-3C-264/25-FM - 2905871
Plug-in lightning current arrester, in accordance with Type 1/Class I, with integrated surge-proof fuse, for 3-phase power supply networks with combined PE and N installed in one conductor (L1, L2, L3, PEN).
DT35-B15251 -1057652
Supply voltage Vs DC 12 V ... 30 V 1) 2)
Ripple ≤ 5 Vpp 3)
Power consumption ≤ 1.7 W 4)
Initialization time ≤ 500 ms
Warm-up time ≤ 20 min
Housing material Plastic (ABS/PC)
Window material Plastic (PMMA)
Connection type Male connector, M12, 5-pin
Indication LEDs
Weight 65 g
Dimensions (W x H x D) 32 mm x 58.67 mm x 42.7 mm
Enclosure rating IP65/IP67
SAC-3P- 5,0-PVC/M12FS - 1400505
Sensor/actuator cable, 3-position, PVC, black RAL 9005, free cable end, on Socket straight M12, coding: A, cable length: 5 m
DT35-B15551 - 1057651
Mechanics/electronics
Supply voltage Vs DC 12 V ... 30 V 1) 2)
Ripple ≤ 5 Vpp 3)
Power consumption ≤ 1.7 W 4)
Initialization time ≤ 500 ms
Warm-up time ≤ 20 min
Housing material Plastic (ABS/PC)
Window material Plastic (PMMA)
Connection type Male connector, M12, 5-pin
Indication LEDs
Weight 65 g
Dimensions (W x H x D) 32 mm x 58.67 mm x 42.7 mm
Enclosure rating
IP65
IP67
Protection class III
1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
2) When using IO-Link output Vs > 18 V. When using analog voltage output Vs > 13 V.
3) May not fall short of or exceed VS tolerances.
4) Without load, at +20 °C.
Performance
Measuring range
50 mm ... 12,000 mm, 90 % remission 1) 2)
50 mm ... 5,300 mm, 18 % remission
50 mm ... 3,100 mm, 6 % remission
Target Natural objects
Resolution 0.1 mm
Repeatability ≥ 0.5 mm 2) 3) 4)
Accuracy Typ. ± 10 mm 4)
Response time 4.5 ms ... 192.5 ms, 4.5 ms / 12.5 ms / 24.5 ms / 48.5 ms / 192.5 ms 5) 6)
Switching frequency 166 Hz/50 Hz/25 Hz/12 Hz/3 Hz 5) 6)
Output time 2 ms ... 64 ms, 2 ms/4 ms/8 ms/16 ms/64 ms 5) 7)
Light source Laser, red 8)
visible red light
Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance) 15 mm x 15 mm (at 2 m)
Additional function Set speed: Super Fast ... Super Slow, teach-in of analog output and invertible analog output, Output Q2 adaptable: Current output / Voltage output / Digital output, Switching mode: Distance to Object (DtO) / switching window / object between sensor and background (ObSB), teach-in of digital output and digital output invertible, Multifunctional input: laser off / external teach / deactivated, reset to factory default
Average laser service life (at 25 °C) 100,000 h
1) For speed setting Slow.
2) See repeatability characteristic lines.
3) Equivalent to 1 σ.
4) 6 % ... 90 % remission.
5) Depending on the set speed: Super Fast ... Super Slow.
6) Lateral entry of the object into the measuring range.
7) Continuous change of distance in measuring range.
8) Wavelength: 658 nm; max. output: 250 mW; pulse duration: 3 ns; duty cycle: 1/500.
Interfaces
IO-Link ✔ , IO-Link V1.1
Function Process data, parameterization, diagnosis, data storage
Data transmission rate 38.4 kbit/s
Digital output
Number 1 ... 2 1) 2)
Type Push-pull: PNP/NPN
Function Output Q2 adaptable: Current output / Voltage output / Digital output
Maximum output current IA ≤ 100 mA
Analog output
Number 1
Type Current output / voltage output
Function Output Q2 adaptable: Current output / Voltage output / Digital output
Current 4 mA ... 20 mA, ≤ 450 Ω
Voltage 0 V ... 10 V, ≥ 50,000 Ω
Resolution 12 bit
Multifunctional input (MF) 1 x 3)
Hysteresis 0 mm ... 11,950 mm 4)
1) Output Q short-circuit protected.
2) Voltage drop < 3 V.
3) Response time ≤ 60 ms.
4) Configurable via IO-Link.
Ambient data
Ambient temperature, operation –30 °C ... +55 °C, Uv ≤ 24 V
Ambient temperature, storage –40 °C ... +75 °C
Max. rel. humidity (not condensing) ≤ 95 %
Vibration resistance EN 60068-2-6, EN 60068-2-64
Shock resistance EN 60068-2-27
DOL-2312-G1M5MD1 - 2062240
Technical specifications
Accessory group Plug connectors and cables
Accessory family Connecting cables
Connection type head A Female connector, M23, 12-pin, straight
Connection type head B Flying leads
Locking nut material Zinc die-cast, nickel-plated
Cable 1.5 m, 12-wire, PUR, halogen-free
Jacket material PUR, halogen-free
Jacket color Black
Cable diameter 7.8 mm
Conductor cross-section 4 x 2 x 0.25 mm² + 2 x 0.5 mm² + 2 x 0.14 mm²
Shielding Shielded
Bending radius
Stationary position > 5 x cable diameter
Drag chain operation > 7.5 x cable diameter
Reference voltage
≤ 160 V
Current loading 7 A
Signal type Incremental
Enclosure rating IP66/ IP67
Description Head A: female connector, M23, 12-pin, straight Head B: Cable Cable: incremental, suitable for drag chain, PUR, halogen-free, shielded, 4 x 2 x 0.25 mm² +2 x 0.5 mm² +1 x 0.14 mm², Ø 7.8 mm
DFS60A-THWA32768 - 1074733
Interfaces
Communication interface Incremental
Communication Interface detail HTL / Push pull
Number of signal channels 6-channel
0-set function via hardware pin ✔
0-SET function H-active, L = 0 - 3 V, H = 4,0 - Us V 1)
Initialization time 30 ms
Output frequency ≤ 820 kHz
Load current ≤ 30 mA
Power consumption ≤ 0.7 W (without load)
1) Only with devices with M23 connector in connection with electrical interfaces M, U, V and W.
Electrical data
Connection type Male connector, M23, 12-pin, radial
Supply voltage 4.5 ... 32 V
Reference signal, number 1
Reference signal, position 90°, electric, logically gated with A and B
Reverse polarity protection ✔
Short-circuit protection of the outputs ✔ 1)
MTTFd: mean time to dangerous failure 300 years (EN ISO 13849-1) 2)
1) Short-circuit opposite to another channel, US or GND permissable for maximum 30 s.
2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Mechanical data
Mechanical design Through hollow shaft
Shaft diameter 15 mm
Weight + 0.2 kg
Shaft material Stainless steel
Flange material Aluminum
Housing material Aluminum die cast
Start up torque 0.8 Ncm (+20 °C)
Operating torque 0.6 Ncm (+20 °C)
Permissible movement static
± 0.3 mm (radial)
± 0.5 mm (axial)
Permissible movement dynamic
± 0.05 mm (radial)
± 0.01 mm (axial)
Operating speed ≤ 6,000 min⁻¹ 1)
Moment of inertia of the rotor 40 gcm²
Bearing lifetime 3.6 x 10^10 revolutions
Angular acceleration ≤ 500,000 rad/s²
1) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.
Ambient data
EMC According to EN 61000-6-2 and EN 61000-6-3
Enclosure rating
IP65, Housing side, male connector (IEC 60529) 1)
IP65, shaft side (IEC 60529)
Permissible relative humidity 90 % (Condensation not permitted)
Operating temperature range
–40 °C ... +100 °C 2)
–30 °C ... +100 °C 3)
Storage temperature range –40 °C ... +100 °C, without package
Resistance to shocks 100 g, 6 ms (EN 60068-2-27)
Resistance to vibration 30 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
1) With mating connector fitted.
2) Stationary position of the cable.
3) Flexible position of the cable.
DOL-2312-G1M5MA3 - 2029212
Technical specifications
Accessory group Plug connectors and cables
Accessory family Connecting cables
Connection type head A Female connector, M23, 12-pin, straight
Connection type head B Flying leads
Locking nut material Zinc die-cast, nickel-plated
Cable 1.5 m, 12-wire, PUR, halogen-free
Jacket material PUR, halogen-free
Jacket color Black
Cable diameter 7.8 mm
Conductor cross-section 4 x 2 x 0.25 mm² + 2 x 0.5 mm² + 2 x 0.14 mm²
Shielding Shielded
Bending radius
Stationary position > 5 x cable diameter
Drag chain operation > 7.5 x cable diameter
Reference voltage
≤ 160 V
Current loading 7 A
Signal type Incremental
Enclosure rating IP66/ IP67
Description Head A: female connector, M23, 12-pin, straight Head B: Cable Cable: incremental, suitable for drag chain, PUR, halogen-free, shielded, 4 x 2 x 0.25 mm² +2 x 0.5 mm² +1 x 0.14 mm², Ø 7.8 mm
IMM05-0B8PSVT0S - 1103984
Features
Housing Cylindrical thread design
Housing Standard design
Thread size M5 x 0.5
Diameter Ø 5 mm
Sensing range Sn 0.8 mm
Safe sensing range Sa 0.648 mm
Installation type Flush
Switching frequency 5,000 Hz
Connection type Connector M8, 3-pin
Switching output PNP
Output function NO
Electrical wiring DC 3-wire
Enclosure rating IP67 1)
Special features Visual adjustment indicator, IO-Link
Items supplied
Mounting nut, V2A stainless steel (2x)
Washer, V2A stainless steel, with locking teeth (2x)
1) According to EN 60529.
Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC
Ripple ≤ 20 % 1)
Voltage drop ≤ 2 V 2)
Time delay before availability ≤ 10 ms
Hysteresis 1 % ... 15 %
Reproducibility ≤ 2.5 % 3)
Temperature drift (of Sr) ≤ 10 %
EMC EN 60947-5-2
Continuous current Ia ≤ 200 mA
Short-circuit protection ✔
Reverse polarity protection ✔
Power-up pulse protection ✔
Shock and vibration resistance 30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature –25 °C ... +70 °C
Housing material Stainless steel V2A, DIN 1.4305 / AISI 303
Sensing face material Plastic, LCP
Housing length 38 mm
Thread length 20 mm
Tightening torque, max. ≤ 1.5 Nm
UL File No. NRKH.E348498
1) Of VS.
2) With Ia = 200 mA.
3) Ub and Ta constant.
Safety-related parameters
MTTFD 1,350 years
DCavg 0 %
TM (mission time) 20 years
Communication interface
Communication interface IO-Link V1.1
Communication Interface detail COM2 (38,4 kBaud)
Cycle time 10.4 ms
Process data length 1 Byte
Process data structure
Bit 0 = Sr reached
Bit 1 = Sa reached
Reduction factors
Note The values are reference values which may vary
St37 steel (Fe) 1
Stainless steel (V2A, 304) Approx. 0.72
Aluminum (Al) Approx. 0.49
Copper (Cu) Approx. 0.42
Brass (Br) Approx. 0.56
Installation note
Remark Associated graphic see "Installation"
B 0 mm
C 5 mm
D 2.4 mm
F 3 mm