DFS60A-THWA32768 - 1074733

    This combination does not exist.

    Buy Now

    Interfaces
    Communication interface Incremental
    Communication Interface detail HTL / Push pull
    Number of signal channels 6-channel
    0-set function via hardware pin ✔
    0-SET function H-active, L = 0 - 3 V, H = 4,0 - Us V 1)
    Initialization time 30 ms
    Output frequency ≤ 820 kHz
    Load current ≤ 30 mA
    Power consumption ≤ 0.7 W (without load)
    1) Only with devices with M23 connector in connection with electrical interfaces M, U, V and W.

    Electrical data
    Connection type Male connector, M23, 12-pin, radial
    Supply voltage 4.5 ... 32 V
    Reference signal, number 1
    Reference signal, position 90°, electric, logically gated with A and B
    Reverse polarity protection ✔
    Short-circuit protection of the outputs ✔ 1)
    MTTFd: mean time to dangerous failure 300 years (EN ISO 13849-1) 2)
    1) Short-circuit opposite to another channel, US or GND permissable for maximum 30 s.
    2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.

    Mechanical data
    Mechanical design Through hollow shaft
    Shaft diameter 15 mm
    Weight + 0.2 kg
    Shaft material Stainless steel
    Flange material Aluminum
    Housing material Aluminum die cast
    Start up torque 0.8 Ncm (+20 °C)
    Operating torque 0.6 Ncm (+20 °C)
    Permissible movement static

    ± 0.3 mm (radial)

    ± 0.5 mm (axial)
    Permissible movement dynamic

    ± 0.05 mm (radial)

    ± 0.01 mm (axial)
    Operating speed ≤ 6,000 min⁻¹ 1)
    Moment of inertia of the rotor 40 gcm²
    Bearing lifetime 3.6 x 10^10 revolutions
    Angular acceleration ≤ 500,000 rad/s²
    1) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.

    Ambient data
    EMC According to EN 61000-6-2 and EN 61000-6-3
    Enclosure rating

    IP65, Housing side, male connector (IEC 60529) 1)

    IP65, shaft side (IEC 60529)
    Permissible relative humidity 90 % (Condensation not permitted)
    Operating temperature range

    –40 °C ... +100 °C 2)

    –30 °C ... +100 °C 3)
    Storage temperature range –40 °C ... +100 °C, without package
    Resistance to shocks 100 g, 6 ms (EN 60068-2-27)
    Resistance to vibration 30 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
    1) With mating connector fitted.
    2) Stationary position of the cable.