DFS60A-THWA32768 - 1074733
    Interfaces
    Communication interface	Incremental
    Communication Interface detail	HTL / Push pull
    Number of signal channels	6-channel
    0-set function via hardware pin	✔
    0-SET function	H-active, L = 0 - 3 V, H = 4,0 - Us V 1)
    Initialization time	30 ms
    Output frequency	≤ 820 kHz
    Load current	≤ 30 mA
    Power consumption	≤ 0.7 W (without load)
        1) Only with devices with M23 connector in connection with electrical interfaces M, U, V and W.
    Electrical data
    Connection type	Male connector, M23, 12-pin, radial
    Supply voltage	4.5 ... 32 V
    Reference signal, number	1
    Reference signal, position	90°, electric, logically gated with A and B
    Reverse polarity protection	✔
    Short-circuit protection of the outputs	✔ 1)
    MTTFd: mean time to dangerous failure	300 years (EN ISO 13849-1) 2)
        1) Short-circuit opposite to another channel, US or GND permissable for maximum 30 s.
        2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
    Mechanical data
    Mechanical design	Through hollow shaft
    Shaft diameter	15 mm
    Weight	+ 0.2 kg
    Shaft material	Stainless steel
    Flange material	Aluminum
    Housing material	Aluminum die cast
    Start up torque	0.8 Ncm (+20 °C)
    Operating torque	0.6 Ncm (+20 °C)
    Permissible movement static	
    ± 0.3 mm (radial)
    ± 0.5 mm (axial)
    Permissible movement dynamic	
    ± 0.05 mm (radial)
    ± 0.01 mm (axial)
    Operating speed	≤ 6,000 min⁻¹ 1)
    Moment of inertia of the rotor	40 gcm²
    Bearing lifetime	3.6 x 10^10 revolutions
    Angular acceleration	≤ 500,000 rad/s²
        1) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.
    Ambient data
    EMC	According to EN 61000-6-2 and EN 61000-6-3
    Enclosure rating	
    IP65, Housing side, male connector (IEC 60529) 1)
    IP65, shaft side (IEC 60529)
    Permissible relative humidity	90 % (Condensation not permitted)
    Operating temperature range	
    –40 °C ... +100 °C 2)
    –30 °C ... +100 °C 3)
    Storage temperature range	–40 °C ... +100 °C, without package
    Resistance to shocks	100 g, 6 ms (EN 60068-2-27)
    Resistance to vibration	30 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
        1) With mating connector fitted.
        2) Stationary position of the cable.
        3) Flexible position of the cable.
                Terms and Conditions