DFS60B-TGAA02500 - 1062480
Performance
Pulses per revolution 2,500 1)
Measuring step 90° electric/pulses per revolution
Measuring step deviation at non binary number of lines ± 0.01°
Error limits ± 0.05°
Interfaces
Communication interface Incremental
Communication Interface detail TTL / RS-422
Number of signal channels 6-channel
Initialization time 40 ms
Output frequency ≤ 600 kHz
Load current ≤ 30 mA
Operating current 40 mA (without load)
Electrical data
Connection type Male connector, M23, 12-pin, radial
Supply voltage 4.5 ... 5.5 V
Reference signal, number 1
Reference signal, position 90°, electric, logically gated with A and B
Short-circuit protection of the outputs ✔ 1)
MTTFd: mean time to dangerous failure 300 years (EN ISO 13849-1) 2)