WLL180T-L632 - 6050762
    Features
    Device type	Fiber-optic sensors
    Device type detail	Base unit 1)
    Dimensions (W x H x D)	10.5 mm x 34.6 mm x 71.9 mm
    Housing design (light emission)	Rectangular
    Sensing range max.	0 m ... 20 m (Through-beam system) 2) 3)
    Sensing range	
    0 mm ... 1,400 mm, Proximity system 4) 5)
    0 m ... 18 m, Through-beam system 2) 3)
    Focus	Approx. 65° 6)
    Type of light	Visible red light
    Light source	LED 7)
    Angle of dispersion	Approx. 65° 6)
    Wave length	650 nm
    Adjustment	
    Menu-controlled
    Single teach-in button
    Cable
    Indication	Display
    Display	LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters
        1) Up to 15 expansion units can be connected.
        2) Sensing range with 8 ms response time. Reduction with shorter response time (see tables LL3/WLL180T).
        3) LL3-TX01.
        4) Object with 90% remission (based on standard white DIN 5033). Sensing range at 8 ms response time. Reduced at shorter response times (see LL3 / WLL180T tables).
        5) LL3-DK06.
        6) See LL3 fiber-optic data.
        7) Average service life: 100,000 h at TU = +25 °C.
    Mechanics/electronics
    Supply voltage	12 V DC ... 24 V DC 1)
    Ripple	≤ 10 % 2)
    Current consumption	50 mA 3)
    Switching output	NPN
    Number of switching outputs	2
    Switching mode	Light/dark switching
    Switching mode selector	Manually selectable
    Response time	
    ≤ 16 µs 4)
    ≤ 70 µs
    ≤ 250 µs
    ≤ 2,000 µs
    ≤ 8,000 µs
    Switching frequency	
    31.2 kHz
    7.1 kHz
    2 kHz
    250 Hz
    62.5 Hz
    Time functions	
    Without time delay
    Off delay
    On delay
    ON and OFF delay
    One shot
    Delay time	Programmable, 0 ms ... 9,999 ms
    Input	Multifunctional input MF
    Connection type	Cable, 5-wire, 2 m 5)
    Cable material	PVC
    Conductor cross section	0.2 mm²
    Circuit protection	
    A 6)
    B 7)
    C 8)
    D 9)
    Protection class	III
    Weight	25 g
    Housing material	Plastic, ABS/PC
    Enclosure rating	IP50 10)
    Items supplied	BEF-WLL180 mounting bracket
    Ambient operating temperature	–25 °C ... +55 °C
    Ambient temperature, storage	–40 °C ... +70 °C
    UL File No.	NRKH2.E300503 & NRKH8.E300503
        1) +- 10%.
        2) May not exceed or fall below Uv tolerances.
        3) Without load.
        4) Selectable.
        5) Do not bend below 0 °C.
        6) A = VS connections reverse-polarity protected.
        7) B = inputs and output reverse-polarity protected.
        8) C = interference suppression.
        9) D = outputs overcurrent and short-circuit protected.
        10) With correctly attached fibre-optic cable LL3 and closed protection hood.
                Terms and Conditions
                30-day money-back guarantee
                Shipping: Contact us info@aarkautomation.com
            
Once the user has seen at least one product this snippet will be visible.