Home
Product
Hardware
Controllers
Remote IOs
HMI & IPS
Software
SCADA Software
Programming Software
HMI Softwares
Cloud Solutions
Cloud database
Remote Monitoring
IOT Dashboards
Sensors
Proximity Sensors
1/2/3/4D Sensors
Saftey Sensors
Blog
Courses
Contact us
Jobs
Forum
Events
Shop
0
0
Sign in
Contact Us
Public Price
Public Price
Prev
176
177
178
179
180
181
182
Next
Sort by
Catalog price: High to Low
Catalog price: Low to High
Name: A to Z
Name: Z to A
Show categories
All Products
Plug connectors and cables
Phoenix Contact
PLC/ IO Modules
Power Supplies
Redundancy module
Memory
Program / configuration memory
Safety controller
Antenna cable
Connecting cable
Fan
Multiplexer
Controller
Bus connector
Extension module
Box PC
I/O module
Communication module
Special function module
Safety module
Power module
Starter kit
Module carrier
Cover
Bus coupler
Inline function terminal
Inline terminal
Inline ME terminal
Branch terminal
Potential distributors
Field multiplexer
Distributed I/O device
Feed-through terminal block
End cover
Screw bridge
Insertion bridge
Separating plate
Partition plate
Female test connector
Test plugs
Insulating sleeve
Fixed bridge
Fuse modular terminal block
Fuse terminal block
Lever-type disconnect terminal block
Double-level terminal block
Spacer plate
Knife disconnect terminal block
Disconnect terminal block
Switching jumper
Bolt connection terminal block
Cover profile
Test disconnect terminal block
High Current Connectors
Type 1+2 combined lightning current and surge arrester
Lightning/surge arrester type 1/2
Type 1/2 surge protection plug
Type 2 surge arrester
Type 2 surge protection base element
Power supply unit
Relay base
Relay retaining bracket
Single relay
Plug-in module
Timer relay
Signal conditioner
Repeater power supply
Temperature measuring transducer
Signal duplicator
Marker for terminal blocks
Label
Thermal transfer printer
Magazine
Ink ribbon
Ferrule
Stripping tool
Crimping pliers
End clamp
Industrial Ethernet Switch
Multi-level terminal block
Relay Module
Remote bus cable
Surge protection device
Screwdriver
Antenna
Base unit
Cable
Component terminal block
RJ45 connector
Distribution block
Double-level spring-cage terminal block
Printed-circuit board connector
Interface converters
FO converters
Frequency transducer
Frequency converter
Fuse
Hybrid motor starter
I/O extension module
System package
Miniature solid-state relay
nanoLC module
Operator terminal
Plug-in bridge
Potential collective terminal
Router
Sensor/actuator cable
Connector
Safety relays
Software
Surge protection base-element
Signaling system
Touch panel
Uninterruptible power supply
Type 2 surge protection plug
Wireless module
Cable tie
Zack marker strip
Fork-type cable lug
Continuous plug-in bridge
FO patch cable
DIN rail bus connectors
License
Type 3 surge protection device
Sensor/actuator box
Sensor/actuator terminal block
D-SUB bus connector
Passive module
Ground modular terminal block
Sensor/actuator box header
EXOR
EXOR International
Ex700 Series
Jsmart 700 Series
Esmart Series
HMI Add-Ons Plugins
Mounting brackets and plates
Type 3 surge protection device
SICK Sensors
Encoders
Incremental encoders
Absolute encoders
Proximity sensors
Capacitive proximity sensors
Inductive Proximity Sensors
Contrast Sensors
Fiber-optic Sensors and fibers
Fork sensors
Magnetic Cylinder Sensors
Photoelectric sensors
Distance Sensors
Detection and Ranging Solutions
Displacement measurement sensors OD Mini / OD Mini Prime
Safety Light Curtains
Accessories
level sensors
Fluid sensors
Safety laser scanners
LIT 1X2-24 - 2804610
Surge protection in a one-piece 6.2 mm wide DIN rail module for one floating signal circuit in 2-conductor technology. Tested in accordance with the following types of protection in Ex areas: Ex ia IIC / Ex iaD. HART-compatible.
PT 5-HF-12 DC-ST - 2838775
Protective plug PT with HF protective circuit for 4 signal wires. Nominal voltage: 12 V DC
PTI 2,5-PE/L/L - 3213949
Installation ground terminal block, nom. voltage: 400 V, nominal current: 24 A, Push-in connection, 1st, 2nd and 3rd level, Rated cross section: 4 mm2, cross section: 0.14 mm2 - 4 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray
FLT 100 N/PE CTRL-1.5 - 2856388
Lightning current arrester with encapsulated N-PE spark gap and ignition electronics, 1-channel. Protection level: 1.5 kV. Housing width: 35 mm (2 Div.)
VAL-MS 320 ST - 2838843
Surge protection connector type 2 with high-capacity varistor for VAL-MS base element, thermal monitoring, visual fault warning. Design: 320 V AC
AFS60A-S1PL262144 - 1037501
Performance
Number of steps per revolution (max. resolution) 262,144 (18 bit)
Error limits G 0.03° 1)
Repeatability standard deviation σr 0.002° 2)
1) In accordance with DIN ISO 1319-1, position of the upper and lower error limit depends on the installation situation, specified value refers to a symmetrical position, i.e. deviation in upper and lower direction is the same.
2) In accordance with DIN ISO 55350-13; 68.3% of the measured values are inside the specified area.
Interfaces
Communication interface SSI
Initialization time 50 ms 1)
Position forming time < 1 µs
Code type Gray
Code sequence parameter adjustable CW/CCW (V/R̅) parameter adjustable
Clock frequency ≤ 2 MHz 2)
Set (electronic adjustment) H-active (L = 0 - 3 V, H = 4,0 - Us V)
CW/CCW (counting sequence when turning) L-active (L = 0 - 1,5 V, H = 2,0 - Us V)
1) Valid positional data can be read once this time has elapsed.
2) Minimum, LOW level (Clock +): 250 ns.
Electrical data
Connection type Cable, 8-wire, universal, 3 m 1)
Supply voltage 4.5 ... 32 V DC
Power consumption ≤ 0.7 W (without load)
Reverse polarity protection ✔
MTTFd: mean time to dangerous failure 250 years (EN ISO 13849-1) 2)
1) The universal cable connection is positioned so that it is possible to lay it without bends in a radial or axial direction.
2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Mechanical data
Mechanical design Solid shaft, Servo flange
Shaft diameter 6 mm
Shaft length 10 mm
Weight 0.3 kg 1)
Shaft material Stainless steel
Flange material Aluminum
Housing material Aluminum die cast
Start up torque < 0.5 Ncm (+20 °C)
Operating torque < 0.3 Ncm (+20 °C)
Permissible shaft load
80 N / radial
40 N / axial
Operating speed ≤ 9,000 min⁻¹ 2)
Moment of inertia of the rotor 6.2 gcm²
Bearing lifetime 3.0 x 10^9 revolutions
Angular acceleration ≤ 500,000 rad/s²
1) Based on devices with male connector.
2) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.
Ambient data
EMC According to EN 61000-6-2 and EN 61000-6-3 1)
Enclosure rating
IP65, shaft side (IEC 60529)
IP67, housing side (IEC 60529) 2)
Permissible relative humidity 90 % (Condensation not permitted)
Operating temperature range –40 °C ... +100 °C 3)
Storage temperature range –40 °C ... +100 °C, without package
Resistance to shocks 60 g, 6 ms (EN 60068-2-27)
Resistance to vibration 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
1) EMC according to the standards quoted is achieved if shielded cables are used.
2) For devices with male connector: with mounted mating connector.
3) Stationary position of the cable
IQ40-20BNSKC0K - 1071846
Features
Housing Rectangular
Housing Short-body
Dimensions (W x H x D) 40 mm x 40 mm x 66 mm
Sensing range Sn 20 mm
Safe sensing range Sa 16.2 mm
Installation type Flush
Switching frequency 150 Hz
Connection type Male connector M12, 4-pin
Switching output NPN
Output function NO
Electrical wiring DC 3-wire
Enclosure rating IP67, IP68, IP69K
Special applications Difficult application conditions
Items supplied Push-lock mounting system (1x)
Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC
Ripple ≤ 10 Vpp 1)
Voltage drop ≤ 2 V
Time delay before availability ≤ 50 ms
Hysteresis 3 % ... 15 % 2)
Reproducibility ≤ 2 %
Temperature drift (of Sr) ± 10 %
Continuous current Ia ≤ 200 mA
Short-circuit protection ✔
Reverse polarity protection ✔
Power-up pulse protection ✔
Shock and vibration resistance 30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature –25 °C ... +85 °C
Ambient temperature, storage –40 °C ... +85 °C
Housing material Plastic, PA 66
Sensing face material Plastic, PA 66
Tightening torque, max. 1.8 Nm
Protection class II 3)
UL File No. E348498
1) Of Ub.
2) Of Sr.
3) Reference voltage: 50 V DC.
Safety-related parameters
MTTFD 1,125 years
DCavg 0 %
TM (mission time) 20 years
Reduction factors
Note The values are reference values which may vary
Stainless steel (V2A, 304) Approx. 0.71
Aluminum (Al) Approx. 0.3
Copper (Cu) Approx. 0.25
Brass (Br) Approx. 0.36
Installation note
Remark Associated graphic see "Installation"
A 0 mm
B 40 mm
C 40 mm
D 60 mm
E 0 mm
F 70 mm
FLKM 14-PA-S300 - 2299770
VARIOFACE front adapter, for SIMATIC S 7-300, 2 x 8 channels can be connected.
PTS 1.5/12-5.0-H - 1792960
PCB terminal block, nominal current: 16 A, rated voltage (III/2): 400 V, nominal cross section: 1.5 mm2, number of potentials: 12, number of rows: 1, number of positions per row: 12, product range: PTS 1,5/..-H, pitch: 5 mm, connection method: Push-in spring connection, mounting: Wave soldering, conductor/PCB connection direction: 0 °, color: green, Pin layout: Linear pinning, Solder pin [P]: 2.5 mm, number of solder pins per potential: 1, type of packaging: packed in cardboard
H3 ETH 5 MTR +EP3H3REJ100YE1
HMI H3 0n3 Wired 5mt Ethernet jm
H3 ETH 10 MTR +EP3HREJ200YE1
HMI H3 0N3 Wired 10mt Ethernet JM
JSCAU002 +JSCAU002
JSMART Cable PoE 5m
JSPOU0P +JSPOU0P1
JSmart PoE injector DIN rail mounting
FL WLAN 2011 - 1119248
WLAN access point, client, mesh for USA and Canada, with two external antenna connections (RSMA-F), IP20, WLAN 802.11a, b, g, n, frequency: 2.4 GHz, 5 GHz, connections: COMBICON 9 V DC ... 32 V DC, RJ45: for LAN, web, http/https, CLI, REST API
DFS60A-S1PC65536 -1036761
MPS-025CLTU0 - 1079359
Features
Cylinder type C-slot
Cylinder types with adapter
Round body cylinder
Profile cylinders and tie-rod cylinders
SMC rail CDQ2
SMC rail ECDQ2
Measuring range 25 mm 1)
Housing length 41 mm
Switching output Push-pull: PNP/NPN
Output function Analog, IO-Link, Switching output
Electrical wiring DC 4-wire
Analog output (voltage) 0 V ... 10 V
Analog output (current) 4 mA ... 20 mA
Enclosure rating IP67 2)
Adjustment
Teach-in control panel Teaching in analog outputs
Selecting the current/voltage output
Inverting the analog output
Teaching in digital switching outputs
IO-Link Teaching in 4 switching points
Pin 2 configuration (0 V–10 V, 4 mA–20 mA)
Measuring range (mm) teach-in (analog output)
Disabling teach-in pushbutton
Teach-in modes per output via IO-Link (cylinder switch mode, two point mode, window mode, and single point mode)
1) ± 1 mm.
2) According to EN 60529.
Mechanics/electronics
Supply voltage 12 V DC ... 30 V DC
Power consumption 42 mA, without load
Voltage drop ≤ 2 V
Continuous current Ia ≤ 100 mA 1)
Max. load resistance ≤ 500 Ω Power Output, at 24 V
Min. load resistance ≥ 2 kΩ 2)
Protection class III
Time delay before availability 0.15 s
Required magnetic field sensitivity, typ. 3 mT ... 12 mT
Resolution, typ. ≥ 50 µm
Linearity error, typ. 0.3 mm 3)
Repeat accuracy, typ. 0.1 mm 4)
Sampling rate, typ. 1 ms
Reverse polarity protection Yes
Short-circuit protection Yes
Status indicator LED Yes
Digital switching output Yes
Teach-in Yes
Ambient operating temperature –20 °C ... +70 °C
Shock and vibration resistance 30 g, 11 ms / 10 ... 55 Hz, 1 mm
EMC According to EN 60947-5-7 5)
Connection type Cable, 4-wire, 2 m
Connection type Detail
Deep-freeze property Do not bend below 0 °C
Conductor cross section 0.08 mm²
Cable diameter Ø 2.6 mm
Bending radius With fixed installation > 5 x cable diameter
For flexible use > 10 x cable diameter
Cable outlet Axial
Material
Housing Plastic
Cable PUR
UL File No. NRKH.E181493 & NRKH7.E181493
1) ≤ 100 mA (PUSH); ≥ –100 mA (PULL).
2) Voltage output.
3) At 25 ° C, linearity error (maximum deviation) depending on response curve and minimal deviation function.
4) At 25 ° C, repeatability magnet movement in one direction.
5) The analog measured value can deviate under transient conditions.
Safety-related parameters
MTTFD 244 years
DCavg 0 %
TM (mission time) 20 years
Communication interface
Communication interface IO-Link V1.1
Communication Interface detail COM3
Cycle time 1 ms
Process data length 16 Bit
Process data structure
Bit 0 = switching signal QL1
Bit 1 = switching signal QL2
Bit 2 = switching signal QL3
Bit 3 = switching signal QL4
Bit 4 ... 15 = position (in 50 μm)
SUBCON-PLUS-PROFIB/90/PG/SC - 2313708
D-SUB connector, 9-pos., male connector, 90° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks
SACC-5P-DSI-M12MS/FS-M16 - 1551671
Sensor/actuator control cabinet feed-through, male to female, 5-pos., M12, shielded, A-coded, bipolar/screw mounting with M16 thread
SACC-M12MS-5CON-PG 7-SH - 1693416
Connector, Universal, 5-position, shielded, Plug straight M12, A, Screw connection, knurl material: Nickel-plated brass, cable gland Pg7, external cable diameter 4 mm ... 6 mm
SAC-5P- 5,0-PUR/M12FS SH - 1682951
Sensor/actuator cable, 5-position, PUR halogen-free, black-gray RAL 7021, shielded, free cable end, on Socket straight M12, coding: A, cable length: 5 m
Prev
176
177
178
179
180
181
182
Next