UM30-213113 - 6036918
Mechanics/electronics
Supply voltage Vs DC 9 V ... 30 V 1) 2)
Power consumption ≤ 2.4 W 3)
Initialization time < 300 ms
Design Cylindrical
Housing material
Metal (nickel-plated brass, PBT)
Ultrasonic transducer: polyurethane foam, glass epoxy resin
Thread size M30 x 1.5
Connection type Male connector, M12, 5-pin
Indication LED display, 2 x LED
Weight 150 g
Sending axis Straight
Dimensions (W x H x D) 30 mm x 30 mm x 84 mm
Enclosure rating IP65 / IP67
Protection class III
1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
2) 15 V ... 30 V when using the analog voltage output.
3) Without load.
Performance
Operating range, limiting range 200 mm ... 1,300 mm, 2,000 mm
Target Natural objects
Resolution ≥ 0.18 mm
Repeatability ± 0.15 % 1)
Accuracy ± 1 % 2) 3)
Temperature compensation ✔
Response time 92 ms 4)
Output time 23 ms
Ultrasonic frequency (typical) 200 kHz
Detection area (typical) See diagrams
Additional function Teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), reset to factory default
1) In relation to the current measured value, minimum value ≥ resolution.
2) Referring to current measurement value.
3) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.
4) Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.