OLM200-1002 - 1051658
Mechanics/electronics
Supply voltage Vs DC 18 V ... 30 V 1)
Ripple ≤ 5 Vpp 2)
Power consumption < 5.5 W
Initialization time 3 s
Enclosure rating IP65 (EN 60 529)
Protection class III
1) Limit values, reverse-polarity protected.
2) May not exceed or fall below Uv tolerances.
Performance
Measuring range 0 m ... 10,000 m 1)
Resolution 0.1 mm, 1 mm, 10 mm, 100 mm
Repeatability 0.15 mm 2)
Response time 10 ms 3)
Output time 2.5 ms
Light source LED, red
Accuracy of speed output ± 5 mm/s
Max. movement speed 7 m/s
Reading distance 100 mm, ± 20 mm
Barcode width 30 mm
1) Dependent on the set resolution and transfer protocol.
2) Statistical error 3 s, no warm-up time required.
3) Response time of digital output.
Interfaces
PROFIBUS DP ✔ , DPV0
Digital input Multifunctional input MF2
Digital output
Number 1 1)
Type PNP / NPN
Function Position, speed, control mark Q00 (off), Q01 (on), illumination on/off, service [failure (dirt/LED service life), no barcode tape, over/under temperature, out of measuring range 0 km > position > 10 km, internal error]
Maximum output current IA ≤ 100 mA 2)
1) Via multifunctional output MF1.
2) Outputs MF1 short-circuit protected.
Ambient data
Electromagnetic compatibility (EMC)
EN 61000-6-2
EN 61000-6-4
Ambient temperature, operation –30 °C ... +60 °C 1)
Ambient temperature, storage –40 °C ... +75 °C 2)
Typ. Ambient light immunity ≤ 5,000 lx 3)
Vibration resistance DIN/EN 60068-2-6, DIN/EN 60068-2-64
Shock resistance DIN/EN 60068-2-27
1) Temperatures < –20 °C with 5 min warm up time.
2) Max. 95 % humidity, non-condensing.
3) Typ. value at +25 °C ambient temperature.