DFS60A-THWA32768 - 1074733
Interfaces
Communication interface Incremental
Communication Interface detail HTL / Push pull
Number of signal channels 6-channel
0-set function via hardware pin ✔
0-SET function H-active, L = 0 - 3 V, H = 4,0 - Us V 1)
Initialization time 30 ms
Output frequency ≤ 820 kHz
Load current ≤ 30 mA
Power consumption ≤ 0.7 W (without load)
1) Only with devices with M23 connector in connection with electrical interfaces M, U, V and W.
Electrical data
Connection type Male connector, M23, 12-pin, radial
Supply voltage 4.5 ... 32 V
Reference signal, number 1
Reference signal, position 90°, electric, logically gated with A and B
Reverse polarity protection ✔
Short-circuit protection of the outputs ✔ 1)
MTTFd: mean time to dangerous failure 300 years (EN ISO 13849-1) 2)
1) Short-circuit opposite to another channel, US or GND permissable for maximum 30 s.
2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Mechanical data
Mechanical design Through hollow shaft
Shaft diameter 15 mm
Weight + 0.2 kg
Shaft material Stainless steel
Flange material Aluminum
Housing material Aluminum die cast
Start up torque 0.8 Ncm (+20 °C)
Operating torque 0.6 Ncm (+20 °C)
Permissible movement static
± 0.3 mm (radial)
± 0.5 mm (axial)
Permissible movement dynamic
± 0.05 mm (radial)
± 0.01 mm (axial)
Operating speed ≤ 6,000 min⁻¹ 1)
Moment of inertia of the rotor 40 gcm²
Bearing lifetime 3.6 x 10^10 revolutions
Angular acceleration ≤ 500,000 rad/s²
1) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.
Ambient data
EMC According to EN 61000-6-2 and EN 61000-6-3
Enclosure rating
IP65, Housing side, male connector (IEC 60529) 1)
IP65, shaft side (IEC 60529)
Permissible relative humidity 90 % (Condensation not permitted)
Operating temperature range
–40 °C ... +100 °C 2)
–30 °C ... +100 °C 3)
Storage temperature range –40 °C ... +100 °C, without package
Resistance to shocks 100 g, 6 ms (EN 60068-2-27)
Resistance to vibration 30 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
1) With mating connector fitted.
2) Stationary position of the cable.
3) Flexible position of the cable.
Terms and Conditions