MRS1104C-111011 - 1081208

    This combination does not exist.

    Buy Now

    Features
    Measurement principle HDDM+
    Application Outdoor
    Light source Infrared (850 nm)
    Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014)
    Aperture angle
    Horizontal 275°
    Vertical 7.5° (Over 4 scan layers)
    Scanning frequency 50 Hz, 4 x 12.5 Hz
    Angular resolution

    0.25°

    0.125°, interlaced

    0.0625°, interlaced
    Heating Self-heating
    Working range 0.2 m ... 64 m
    Scanning range
    At 10% remission 16 m
    At 90% remission 30 m
    Spot size 10.4 mrad x 8.7 mrad
    Amount of evaluated echoes 3

    Mechanics/electronics
    Connection type M12 round connectors with swivel connector
    Supply voltage 10 V DC ... 30 V DC
    Power consumption 37 W, typ. 13 W, Start-up phase max. 30 W for 1 s
    Housing AlSi12, optics cover: PC
    Housing color Gray (RAL 7042)
    Enclosure rating

    IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013)

    IP67 (IEC 60529:1989+AMD1:1999+AMD2:2013)
    Protection class III (IEC 61140:2016-11)
    Electrical safety IEC 61010-1:2010-06
    Weight 1.2 kg
    Dimensions (L x W x H) 151.9 mm x 150 mm x 92.5 mm

    Performance
    Scan/frame rate 55,000 measurement point/s ... 165,000 measurement point/s
    Response time

    4 layers, typ. 20 ms 1)

    1 layer, typ. 80 ms
    Systematic error ± 60 mm
    Statistical error ≤ 30 mm
    Integrated application Field evaluation with flexible fields on 4 levels, Data output
    Number of field sets Up to 64 fields
    Simultaneous evaluation cases Up to 16 evaluations
    Filter

    Fog filter

    Particle filter

    Average filter

    Median filter

    Ground reference evaluation

    Edge filter

    Echo filter
    1) Depending on the selected filter settings and the object size.

    Interfaces
    Ethernet ✔ , TCP/IP, UDP/IP
    Function Host, OPC, NTP, Measured data output (distance, RSSI)
    Data transmission rate 10/100 MBit/s
    Digital inputs/outputs I/O (8 (Multiport))
    Output data

    Contamination indication

    IMU (secondary sensor data)
    Optical indicators 2 LEDs
    Configuration software

    SOPAS ET

    Web server (display)

    Ambient data
    Object remission 2 % ... > 1,000 % (Reflector)
    Electromagnetic compatibility (EMC)

    EN 61000-6-2:2005

    EN 61000-6-3:2007+A1:2011
    Vibration resistance
    10 Hz ... 150 Hz, 5 g, 20 frequency cycles 1)
    Shock resistance

    15 g, 11 ms, 6 single shocks/axis 2)

    10 g, 16 ms, 1,000 continuous shocks/axis 2)
    Ambient operating temperature –30 °C ... +50 °C
    Storage temperature –40 °C ... +75 °C
    Ambient light immunity 80 klx
    1) IEC 60068-2-6:2007.
    2) IEC 60068-2-27:2008.

    General notes
    Note on use The sensor does not constitute a safety component as defined by relevant legislation on machine safety.


    Terms and Conditions
    30-day money-back guarantee
    Shipping: Contact us info@aarkautomation.com



    This is a preview of the recently viewed products by the user.
    Once the user has seen at least one product this snippet will be visible.

    Recently viewed Products