TIM361-2134101 - 1071399
Features
Measurement principle HDDM+
Application Outdoor
Light source Infrared (850 nm)
Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014)
Aperture angle
Horizontal 270°
Scanning frequency 15 Hz
Angular resolution 0.33°
Working range 0.05 m ... 10 m
Scanning range
At 10% remission 8 m
Mechanics/electronics
Connection type
1 x “Ethernet” connection, 4-pin M12 female connector
1 x connection “Power”, 12-pin, M12 male connector
1 x Micro USB female connector, type B
Supply voltage 9 V DC ... 28 V DC
Power consumption Typ. 4 W, 16 W with 4 max. loaded digital outputs
Housing color Gray (RAL 7032)
Enclosure rating IP67, applies only when the plastic cover of the “Aux interface” is closed (IEC 60529:1989+AMD1:1999+AMD2:2013)
Protection class III (IEC 61140:2016-1)
Weight 250 g, without connecting cables
Dimensions (L x W x H) 60 mm x 60 mm x 86 mm
Performance
Response time
1 scan, typ. 67 ms
2 scans, ≤ 134 ms 1)
Detectable object shape Almost any
Systematic error ± 60 mm 2)
Statistical error < 20 mm 2)
Integrated application Field evaluation with flexible fields
Number of field sets 16 field triples (48 fields, contour as reference; 1 triple (3 flexible fields) can be configured directly at the scanner)
Simultaneous evaluation cases
1 (3 fields)
2 (2 fields for detection and 1 field for contour as reference)
1) At +45° to +225° of the working range; max. 150 ms at –45° to +45° of the working range.
2) Typical value at 90% remission up to maximum scanning range; real value depends on ambient conditions.
Interfaces
Ethernet ✔ , TCP/IP
Function AUX, parameterization
USB ✔
Remark Micro USB
Function AUX, parameterization
Digital inputs 4
Digital outputs 3 (PNP, additional 1 x “Device Ready”)
Delay time 67 ms ... 30,000 ms (configurable)
Dwell time 67 ms ... 600,052 ms (configurable)
Optical indicators 2 LEDs (ON, switching status)
Ambient data
Object remission 4 % ... 1,000 % (reflectors)
Electromagnetic compatibility (EMC)
Emitted radiation Residential area (EN 61000-6-3:2007+AMD:A1:2011)
Electromagnetic immunity Industrial environment (EN 61000-6-2:2005)
Vibration resistance
Sine resonance scan 10 Hz ... 1,000 Hz 1)
Sine test 10 Hz ... 500 Hz, 5 g, 10 frequency cycles 1)
Noise test 10 Hz ... 250 Hz, 4.24 g RMS, 5 h 2)
Shock resistance
50 g, 11 ms, ± 3 single shocks/axis 3)
25 g, 6 ms, ± 1,000 continuous shocks/axis 3)
50 g, 3 ms, ± 5,000 continuous shocks/axis 3)
Ambient operating temperature –25 °C ... +50 °C 4)
Storage temperature –40 °C ... +75 °C 4)
Switch-on temperature –10 °C ... +50 °C
Temperature change –25 °C ... +50 °C, 10 cycles 5)
Damp heat +25 °C ... +55 °C, 95 % rF, 6 cycles 6)
Permissible relative humidity
Operation < 80 %, Non-condensing (EN 60068-2-30:2005)
Storage ≤ 90 %, Non-condensing (EN 60068-2-30:2005)
Ambient light immunity 80,000 lx
1) IEC 60068-2-6:2007.
2) IEC 60068-2-64:2008.
3) IEC 60068-2-27:2008.
4) IEC 60068-2-14:2009.
5) EN 60068-2-14:2009.
6) EN 60068-2-30:2005.
General notes
Note on use The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
Terms and Conditions
30-day money-back guarantee
Shipping: Contact us info@aarkautomation.com
Once the user has seen at least one product this snippet will be visible.